Please visit support.cavallo.com

Start a conversation

ShipCenter - How to Enable USB Redirect for Remote Desktop

The following article provides steps for customer environments wherein ShipCenter users ("shippers") work on a PC with a USB Scale connected to it, and run the ShipCenter application via Remote Desktop client.

In order for the shipper's "local" USB Scale to communicate with ShipCenter via Remote Desktop several changes will need to be performed under Group Policy Management on both the local PC and the Remote Desktop

Additionally, the RDP connection used by the local PC will need to be modified after completing the Group Policy changes. 

Changing the above settings may require elevated permissions and should be done with your organization's IT review and approval.

(These changes can be deployed via Group Policy, please work with your internal IT resources on a deployment strategy fit for your organization, number of local PCs, etc.)


Group Policy Management

1. On the Remote Desktop hosting ShipCenter, use Win+R to open to open the Run menu, type gpedit.msc, and press Enter on the keyboard


2. Navigate the Group Policy Editor and then drill-down to:

Administrative Templates ﹥ Windows Components ﹥Remote Desktop Services ﹥ Remote Desktop Connection Client ﹥ RemoteFX USB Device Redirection

With RemoteFX USB Device Redirection selected on the left-hand pane, click Edit Policy Setting or double-click the Setting entry in the right-hand pane of the Group Policy Editor.


3. Enable the policy and set the RemoteFX USB Redirection Access Rights Option to Administrators and Users and click OK.


4. Repeat steps 1-3 on all shipper PCs with USB scales connected to them.

5. Reboot all effected PCs, including the Remote Desktop.


Modify Remote Desktop Connection(s)

The RDP connection on the shipper PC(s) to connect to the Remote Desktop hosting ShipCenter will need the following changes made to it:


1. Open the RDP connection and if necessary click Show Options, then navigate to the Local Resources tab

2. Click the More... button under Local devices and resources3. Click the + to expand the list of entries under Other supported RemoteFX USB devices, locate the USB Scale in the list, check the box next to it's entry and click OK.

4. On the Remote Desktop Connection General tab, click Save to save the changes made to the connection file.

5. Repeat these steps on each shipper PC, selecting the appropriate USB Scale entry.


For additional ShipCenter USB Scale functionality, see ShipCenter Supported Scales

Choose files or drag and drop files
Was this article helpful?
Yes
No
  1. Professional Services

  2. Posted

Comments